Showing 1 - 20 of 66 product(s)


Blue Strobe Single-Zone Refrigerant Monitor HZ687 | Johnston Equipment

Bacharach

Blue Strobe Single-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm, Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 500' (0 to 150 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 7.7" × 3.6" (350 × 195 × 95 mm)

Model: HZ687

Mfr. Model No.: 3015-5804

Sold as: Each

0 In Stock


Red Strobe Single-Zone Refrigerant Monitor HZ688 | Johnston Equipment

Bacharach

Red Strobe Single-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm, Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 500' (0 to 150 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 7.7" × 3.6" (350 × 195 × 95 mm)

Model: HZ688

Mfr. Model No.: 3015-3076

Sold as: Each

0 In Stock


Surface Mount Single-Zone Refrigerant Monitor HZ689 | Johnston Equipment

Bacharach

Surface Mount Single-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm, Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 500' (0 to 150 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 7.7" × 3.6" (350 × 195 × 95 mm)

Model: HZ689

Mfr. Model No.: 3015-5490

Sold as: Each

0 In Stock


Panel Mount Single-Zone Refrigerant Monitor HZ690 | Johnston Equipment

Bacharach

Panel Mount Single-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm, Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 500' (0 to 150 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 7.7" × 3.6" (350 × 195 × 95 mm)

Model: HZ690

Mfr. Model No.: 3015-5491

Sold as: Each

0 In Stock


Tower Mount Panel Light HZ691 | Johnston Equipment

Bacharach

Tower Mount Panel Light

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ691

Mfr. Model No.: 3015-6143

Sold as: Each

0 In Stock


Blue Lens Horn & Strobe Multi-Zone Refrigerant Monitor HZ692 | Johnston Equipment

Bacharach

Blue Lens Horn & Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ692

Mfr. Model No.: 3015-8041

Sold as: Each

0 In Stock


Red Lens Horn & Strobe Multi-Zone Refrigerant Monitor HZ693 | Johnston Equipment

Bacharach

Red Lens Horn & Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ693

Mfr. Model No.: 3015-8043

Sold as: Each

0 In Stock


Amber Lens Horn & Strobe Multi-Zone Refrigerant Monitor HZ694 | Johnston Equipment

Bacharach

Amber Lens Horn & Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ694

Mfr. Model No.: 3015-8042

Sold as: Each

0 In Stock


Blue Lens Strobe Multi-Zone Refrigerant Monitor HZ695 | Johnston Equipment

Bacharach

Blue Lens Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ695

Mfr. Model No.: 3015-8044

Sold as: Each

0 In Stock


Red Lens Strobe Multi-Zone Refrigerant Monitor HZ696 | Johnston Equipment

Bacharach

Red Lens Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ696

Mfr. Model No.: 3015-8046

Sold as: Each

0 In Stock


Amber Lens Strobe Multi-Zone Refrigerant Monitor HZ697 | Johnston Equipment

Bacharach

Amber Lens Strobe Multi-Zone Refrigerant Monitor

  • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
  • Resolution: 1 ppm
  • Sampling Distance: 0 to 1,200' (0 to 365 m)
  • Working Temperature Range: 32 to 122°F (0 to 50°C)
  • Dimensions: 13.7" × 12.3" × 5" (350 × 315 × 130 mm)

Model: HZ697

Mfr. Model No.: 3015-8045

Sold as: Each

0 In Stock


Eco-2020™ Refrigerant Recovery Unit IC449 | Johnston Equipment

Bacharach

Eco-2020™ Refrigerant Recovery Unit

  • Compressor Type: 2-Cylinder
  • Motor: 1 HP
  • Power: 110 - 120 Vac
  • Compatible Refrigerants Category III: R-12, R-134a, R-401C, R-406A, R-500
  • Compatible Refrigerants Category IV: R-22, R-401A, R-401B, R-402B, R-407C, R-407D, R-408A, R-409A, R-411A, R-411B, R-412A, R-502, R-509
  • Compatible Refrigerants Category V: R-402A, R-404A, R-407A, R-407B, R-410A, R-507
  • Recovery Rates (Vapor/Liquid/Push-Pull): 0.55/6.35/11.40 lbs./min (R-22), 0.46/4.52/10.89 lbs./min (R-134a), 0.55/5.71/15.85 lbs./min (R-134a)
  • Dimensions: 16.1 x 10.3 x 13.8" (41 x 26 x 35 cm)
  • Weight: 28.5 lbs. (12.9 kg)
  • Operating Conditions: 32 - 104°F (0 - 40°C), 0 - 95% RH (Non-Condensing), 1 ATM ± 10%
  • Manufacturer's Warranty: 1 Year

Model: IC449

Mfr. Model No.: 2020-8000

Sold as: Each

0 In Stock


True Spot<sup>®</sup> Smoke Tester IC448 | Johnston Equipment

Bacharach

True Spot® Smoke Tester

  • Display: Analogue
  • Measurement: Indicates Smoke Level on a Scale of 0 to 9
  • Common Fuels Requiring Smoke Tests: Oil 2, Oil 4, Oil 6, Kerosene
  • Dimensions: 14 x 2.75 x 1.5" (35.6 x 7 x 3.8 cm) with Sample Tube in Clip and Handle Fully Depressed
  • Sample Tube Length: 11.5" (29.2 cm)
  • Weight: 1 lbs. (0.45 kg)
  • Manufacturer's Warranty: 1 Year

Model: IC448

Mfr. Model No.: 0021-7006

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> InTech<sup>®</sup> Combustion Analyzer Kit IC442 | Johnston Equipment

Bacharach

Fyrite® InTech® Combustion Analyzer Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Oxygen
  • Measurement: 0 - 20.9% (O₂)
  • Fuels: Natural Gas, Oil 2/6, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors)

Model: IC442

Mfr. Model No.: 0024-8510

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> InTech<sup>®</sup> Combustion Analyzer Kit IC443 | Johnston Equipment

Bacharach

Fyrite® InTech® Combustion Analyzer Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Carbon Monoxide/Oxygen
  • Measurements: 0 - 20.9% (O₂), 0 - 2000 ppm (CO)
  • Fuels: Natural Gas, Oil 2/6, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors)

Model: IC443

Mfr. Model No.: 0024-8511

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> InTech<sup>®</sup> Combustion Analyzer Reporting Kit IC444 | Johnston Equipment

Bacharach

Fyrite® InTech® Combustion Analyzer Reporting Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Carbon Monoxide/Oxygen
  • Measurements: 0 - 20.9% (O₂), 0 - 2000 ppm (CO)
  • Fuels: Natural Gas, Oil 2/6, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors)

Model: IC444

Mfr. Model No.: 0024-8512

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> InTech<sup>®</sup> Combustion Analyzer Kit IC445 | Johnston Equipment

Bacharach

Fyrite® InTech® Combustion Analyzer Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Carbon Monoxide/Oxygen
  • Measurements: 0 - 20.9% (O₂), 0 - 2000 ppm (CO)
  • Fuels: Natural Gas, Oil 2/6, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors)

Model: IC445

Mfr. Model No.: 0024-8523

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> Insight<sup>®</sup> Plus Combustion Analyzer Reporting Kit IC441 | Johnston Equipment

Bacharach

Fyrite® Insight® Plus Combustion Analyzer Reporting Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Carbon Monoxide/Oxygen
  • Measurements: 0 - 20.9% (O₂), 0 - 4000 ppm (CO with Integrated NOx filter)
  • Fuels: Natural Gas, Coal, Oil 2/4/6, Wood, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel, +2 Optional Custom Fuels
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors), 3 Years (Long-Life O₂ Sensor)

Model: IC441

Mfr. Model No.: 0024-8518

Sold as: Each

0 In Stock


Fyrite<sup>®</sup> Insight<sup>®</sup> Plus Combustion Analyzer Kit IC440 | Johnston Equipment

Bacharach

Fyrite® Insight® Plus Combustion Analyzer Kit

  • Display: Digital
  • Operating Temperature: ± -5 °C to ±45 °C (± 23 °F to ±113 °F)
  • Additional Gases: Carbon Monoxide/Oxygen
  • Measurements: 0 - 20.9% (O₂), 0 - 4000 ppm (CO with Integrated NOx filter)
  • Fuels: Natural Gas, Coal, Oil 2/4/6, Wood, Kerosene, Propane, Butane, LPG, B5, KOKS, LEG, Biofuel, +2 Optional Custom Fuels
  • Run Time: 15 hrs.
  • Dimensions: 8 x 3.6 x 2.3" (20.3 x 9.1 x 5.8 cm)
  • Weight with Batteries: 1 lbs. (0.45 kg)
  • Operating Conditions: 15 to 90% RH (Non-Condensing), 1 ATM ± 10%
  • Warm-Up Time: 30 - 60 seconds
  • Manufacturer's Warranty: 2 Years (Including Sensors), 3 Years (Long-Life O₂ Sensor)

Model: IC440

Mfr. Model No.: 0024-8517

Sold as: Each

0 In Stock


PCA<sup>®</sup> 400 Active Sample Conditioner Kit IC439 | Johnston Equipment

Bacharach

PCA® 400 Active Sample Conditioner Kit

  • Dimensions: 3.2 x 6 x 6" (81 x 152 x 15 mm)
  • Weight: 10 oz (284 g)
  • Control Temperature: 41°F (5°C) Nominal Cooler Temperature
  • Catch Pot Capacity: 35 ml
  • Power Supply: AC/DC Adapter, 100-264 VAC Input, 15 V, 90 W DC Output
  • Storage Temperature: 14 - 122°F (-10 - 50°C)
  • Storage Humidity: 10 - 90% RH (Non-Condensing)
  • Operating Temperature: 41 - 104° F (5 - 40°C)
  • Operating Humidity: 10 - 90% RH (Non-Condensing)

Model: IC439

Mfr. Model No.: 0024-8558

Sold as: Each

0 In Stock